-12-
Installation
CO-LINEAR VENT SYSTEM
1. Carefully extend the exhaust and combustion air intake pipes to
total chimney length required.
2. Slide the combustion air intake pipe over termination cap collar.
Secure to termination cap with three (3) self-tapping screws.
3. Place a bead of high temperature sealant around the inner edge
at the end of the exhaust pipe and slide onto the termination cap.
4. Secure the exhaust pipe to termination cap with the three (3) self-
tapping screws. Apply additional high temperature sealant around
joint to ensure a proper seal.
5. Complete vent system installation as shown in this manual.
REMOVE AIR DUCT
Remove the air duct at the top of appliance by sliding the air duct
back out of channels. Refer to the following instructions for vent system
attachment to the air duct.
RUN VENT SYSTEM
If offsets are present in existing chimney, place a weighted rope
around the pipe ends to guide them through the chimney. DO NOT
ATTEMPT TO TIE ONE ROPE AROUND BOTH PIPES.
• To prevent cold air drafts, it is recommended to insulate the 3” x 3”
flexible vent pipes and chimney using unfaced insulation products
listed as noncombustible per ASTM E 136.
1. OPTIONAL: Before installing vent system down through the
chimney, place unfaced insulation around the first 3 ft (914 mm) of
vent system below termination cap. Secure with wire.
2.
Install the 3” x 3” flexible pipes down through existing chimney.
Guide ropes (if used) to aid installation.
3. To secure chimney termination cap to chimney, apply a liberal
bead of high temperature sealant around the top of the chimney.
Set termination cap into position as instructed by vent system
manufacturer’s installation manual.
4.
From inside the existing fireplace, carefully pull ropes (if used) or
the flexible pipes down until both exhaust pipe and combustion air
intake are into the existing fireplace firebox.
5. OPTIONAL: To prevent heat loss up chimney, place unfaced
insulation products between the 3” x 3” flexible vent pipes and
chimney.
EX = Exhaust Pipe
CAUTION: All information outlined in the “Installation Preparation”
section of this manual must be completed before continuing with
this installation.
CAUTION: Proper operation of this insert requires the exhaust and
combustion air pipes to be connected to the correct collar, on both
the termination kit and the gas fireplace insert air duct. The fireplace
insert air duct exhaust is located on the right side. Install termination
cap on the right side
Chimney Vent Run