16.4 Programming
Partitions
If you are using a partitioned system then you can use the
following commands for programming the partitions.
1. Use the commands 01 to 16 and X17 to X32 to assign
a partition to each zone.
- each zone belongs to partition A (factory setting).
- Press key A to assign zones to partition A. Use keys
B, C and D to assign zones to the respective partition.
2. Use command 32 to assign control units to partitions.
In the default setting, all control units belong to all
partitions.
3. Programming from exit mode, alarm reaction and exit
time:
Partition
A
B
C
D
Exit
mode
Com. 39
Com. 62
Com. 72
Com. 76
Alarm
reaction
Com. 47
Com. 63
Com. 73
Com. 77
Exit time
Com. 44
Com. 65
Com. 75
Com. 79
4. You can assign siren outputs to each partition using
commands 81 to 84.
- Option 18 assigns the output to partition A.
- Option 19 assigns the output to partition B.
- Option 20 assigns the output to partition C.
- Option 21 assigns the output to partition D.
5. Make sure that the main user is instructed on how to
assign individual user codes to partitions.
Command changes for partitioned systems
Some commands provide new functions for partitioned systems and some commands can no longer be used. The following
table gathers together the differences in the programming:
Command
Partition System
Single System
01-40 zone programming
A – D = partitions
A – D = sections of locations
28 mask out the status display
partition active
location active
32 control units and partitions
control unit assigned to part.
B
no function
39 location/partition A exit mode
option 3 and 4 possible
option 3 becomes Lockset
option 4 is not possible
47 partition A alarm report
function possible
no function
60 zone behaviour for internal B (last exit)
no function
function possible
61 zone behaviour for internal B (entry zone)
no function
function possible
62 exit mode for internal B
options changed
63 alarm behaviour for internal B
options changed
70 zone behaviour for internal C (last exit)
no function
function possible
71 zone behaviour for internal C (entry zone)
no function
function possible
72 exit mode for internal C
options changed
73 alarm behaviour for internal C
options changed
76 exit mode for internal D
options changed
77 Alarm behaviour for internal D
options changed
81, 82, 83, 84 exits
18-21=Siren Partition
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...