79
UK
153 Additional outputs
Additional output 3
154 Additional outputs
Additional output 4
155 Additional outputs
Additional output 5
156 Additional outputs
Additional output 6
157 Additional outputs
Additional output 7
158 Additional outputs
Additional output 8
159 Inverting additional outputs
You can also invert the additional transistor outputs for
different applications. In inverted state, the voltage of
+12V is applied in active state – e.g.: for addressing a
visual signal.
1. On the control unit, enter:
159
2. The LCD display shows: 159: INV Pgby OFF
3. Via the keypad, select from the following items
and press:
00
inv Pgby OFF
+12V voltage is removed for activating
the output. In deactivated state, the
output is set to +12V.
01
Inv Pgby ON
+12V voltage is applied for activating
the output. In deactivated state, the
output is set to ground.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
160 Time-confirmed alarm
To change the settings:
1. On the control unit, enter:
160
2. The LCD display shows: 160:Confrm t=30
3. Via the keypad, select from the following items
and press:
000-
999
Bestät=000-999
The timer starts when an alarm has
been triggered for the first time. If
another alarm is triggered before the
time has expired then the alarm centre
transmits a confirmed alarm to the
central station (command 89=1)
4. Confirm your input. On the control unit, enter:
.
161 Confirm internal loudspeaker
To change the settings:
1. On the control unit, enter:
161
2. The LCD display shows: 161:Conf Int OFF
3. Via the keypad, select from the following items
and press:
0
Conf Int OFF
Internal loudspeaker is on for
unconfirmed alarm (command 89=1)
1
Conf Int OFF
Internal loudspeaker is on for confirmed
alarm (command 89=1)
4. Confirm your input. On the control unit, enter:
.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...