48
UK
4. Apart from the zone properties and zone
attributes, you can make further settings for some
zone properties. For example, for an “entry/exit”
zone and an “entry to follow” zone, you have to
define the entry delay time, and for a “shock
sensor” zone, you have to define the sensitivity..
Enter the additional properties via the keypad as
follows:
X7
For zones with the zone property
“entry/exit” or “entry to follow”, program
the respective entry delay time group.
Then press:
1
for delay group 1
2
for delay group 2
3
for delay group 3
4
for delay group 4
X7
For zones with the zone property
“shock sensor”, set the sensitivity. Then
press:
1
insensitive
6
sensitive
5.
Confirm your input. On the control unit, enter:
.
IMPORTANT:
The delay time for the entry/exit zone
should be longer than the delay time for
the entry to follow zone.
Set the
time for the entry delay time group in
items 201 to 204.
020 Changing the program code
To change the program code required to open the
program menu. From the program level, do the following:
1. On the control unit, enter:
020
2. The LCD display shows: 020: CODE
3. The cursor flashes at the end of the setting.
4. Enter the new four-digit program code via the
keypad.
5. Confirm your input. On the control unit, enter:
.
6. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
021 Changing the zone termination
For changing the zone termination for the inputs of the
burglar alarm centre. From the program level, do the
following:
1. On the control unit, enter:
021
2. The LCD display shows: 021:CC+ComA/T
3. Via the keypad, select from the following items
and press:
00
CC+ComA/T
For this zone termination, no resistor
can be inserted in the alarm zone. An
alarm is triggered if the zone is opened.
The tamper contact of the sensor must
be connected separately to the burglar
alarm centre.
See the connection diagrams for
connecting with CC+ComA/T..
01
FSL 2K2/4K7
For this zone termination, two resistors
with different values must be used. The
burglar alarm centre triggers alarm or
tampering, depending on which
resistance value is changed. The
tamper input at the alarm centre is out
of action.
See the connection diagrams for
connecting with DEOL.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...