58
UK
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
054 BVVO monitoring
To change the property of the BVVO monitoring:
1. On the control unit, enter:
054
2. The LCD display shows: 054: BVVO Sup OFF
3. Via the keypad, select from the following items
and press:
0
BVVO Sup OFF
If a radio transmitter can no longer be
reached by the alarm centre then this
reports a monitoring error after 1 hour
(see function 128).
1
BVVO Sup ON
If a radio transmitter can not be reached
for more than 15 minutes then a
warning is displayed on the control unit
if an attempt is made to activate it. If the
transmitter can not be reached for more
than 2 hours then the alarm centre
reports: „detector tampering“, (when
activated) external alram; „monitoring
error“, (when deactivated) internal
alarm.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
056 Length of access code
To change the property of the length of the access code:
1. On the control unit, enter:
056
2. The LCD display shows: 056: 4 Digit
3. Via the keypad, select from the following items
and press:
0
4 Digit
1
6 Digit
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
IMPORTANT:
Changing the length of the access code
requires that all codes be reset to the factory settings.
From the factory: 4 numbers (1234 for user, 7890 for
installer); 6 numbers (123456 for user, 567890 for
installer).
057 Battery test
To change the property of the battery test:
1. On the control unit, enter:
057
2. The LCD display shows: 057: BattTest OFF
3. Via the keypad, select from the following items
and press:
0
BattTest OFF
No battery test is carried out.
1
BattTest ON
A battery test is carried out if
deactivated or 23 hours after the last
test (neg.: display „battery fault“ in the
control unit + short tone)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...