5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
037 Sabotage Report deactivated
To change this feature, proceed as follows:
1. On the control unit, enter:
037
2. The LCD display shows: 037:Day Tamp OFF
3. Via the keypad, select from the following items
and press:
0
Day Tamp OFF
In case of tampering when the alarm
centre is deactivated, this only issues
an internal alarm.
1
Day Tamp ON
In case of tampering when the alarm
centre is deactivated, this issues an
internal alarm and reports the
tampering to the central station.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
038 System Sabotage Reset
To change the property of the System Sabotage Reset:
1. On the control unit, enter:
038
2. The LCD display shows: 038: EnSysTmp ON
3. Via the keypad, select from the following items
and press:
0
EnSysTmp OFF
In the event of a system sabotage, you
can reset the alarm centre by entering
the user code.
1
EnSysTmp ON
In the event of a system sabotage, you
can reset the alarm centre by entering
the installer code.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
039 Exit mode for overall activated (A)
To change the property of the exit mode for overall
activated:
1. On the control unit, enter:
039
2. The LCD display shows: 039: A=Timed
3. Via the keypad, select from the following items
and press:
0
A=Timed
After the alarm centre is activated, the
programmed exit delay time starts. At
the end of the delay time, the alarm
centre is activated. If zones are open at
this time, an alarm is triggered.
1
A=Terminated
After the alarm centre is activated, the
exit delay time starts. The delay time
runs until a button connected to a
control unit is pressed, which ends the
exit delay time manually. The exit delay
time ends seven seconds after the
button is pressed.
2
A=Final Door
After the alarm centre is activated, the
exit delay time starts. The delay time
runs until a zone with the entry/exit
property is closed. The exit delay time
ends seven seconds after the zone is
closed.
3
A=Lock Set
After the alarm centre is activated, the
delay time starts. The delay time runs
until a zone with the entry/exit property
is closed and, after the zone has
closed, a contact connected to the
control unit is opened.
4. Confirm your input. On the control unit, enter:
.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...