50
UK
027 Alarm on failed activation
To change the property of the alarm on failed activation,
proceed as follows:
1. On the control unit, enter:
027
2. The LCD display shows: 027:Internal
3. Via the keypad, select from the following items
and press:
0
Internal
If activation fails, the alarm is issued via
the internal signaller.
1
Local
If activation fails, the alarm is also
issued via the external siren.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
028 Status display
Proceed as follows to change the property of the status
display:
1. On the control unit, enter:
028
2. The LCD display shows: 028:Status OFF
3. Via the keypad, select from the following items
and press:
0
Status OFF
The display is permanently on. The
system always shows whether the
alarm centre is activated or deactivated.
1
Status ON
The status display of the alarm centre
remains active for 180 seconds after
entry of the user code, and then
changes to date and time display.
2
Status Code
30 seconds after each event, the
display changes back to date and time
display. Note that the LEDs also light
for 30 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
029 Entry alarm delay
Proceed as follows to change the property of the entry
alarm delay:
1. On the control unit, enter:
029
2. The LCD display shows: 029:Delay OFF
3. Via the keypad, select from the following items
and press:
0
Delay OFF
The alarm centre generates an
immediate alarm if the user deviates
from the specified entry route.
1
Delay ON
The alarm centre extends the entry
delay by 30 seconds if the user
deviates from the specified entry route.
An internal alarm is triggered to inform
the user that he/she has made a
mistake. If the user code is entered
within the delay time, a local alarm is
prevented and the alarm centre is reset.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...