71
UK
3. The LCD display shows: 101: Comms=OFF
4. Via the keypad, select from the following items
and press:
0
Comms=OFF
The alarm centre does not use any
communication devices.
1
Comms=Single
Single report. The alarm centre reports
to a programmed telephone number
(command 115) with an access number
(command 117). The alarm centre dials
the number and attempts to establish a
connection to the central station (max.
15 attempts).
2
Comms=ALT
The alarm centre dials one of two
programmed numbers and attempts to
establish a connection to the central
station. If the attempt is unsuccessful
then the alarm centre dials the second
of the two numbers (max 15 attempts
for each number). If the connection is
successful and the alarm is confirmed
then the connection is subsequently
closed.
3
Comms=Dual
Dual Report. As in item 2, 2 numbers
are dialled and an attempt is made to
establish a connection to the central
stations. However, both central stations
must have successfully confirmed the
alarm (max. 15 attempts until both have
successfully confirmed).
5. Confirm your input. On the control unit, enter:
.
6. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
103 Format Report
Proceed as follows to change the property of the format
report:
1. On the control unit, enter:
103
2. The LCD display shows: 126:Format=FF
3. Via the keypad, select from the following items
and press:
0
Format=FF
Fast format
1
Format=CID
Contact ID
2
Format=SIAI1
Scancom SIA Level I
3
Format=SIA2
Scancom SIA Level 2 (transmits no
time+date)
4
Format=SIA3
Scancom SIA Level 3
5
Format=XSIS3
Extended Scancom SIA Level 3
6
Format=Hbeep
Home „beep“ No particular format. The
alarm centre dials a number and
transmits a „beep“ See command 186.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...