76
UK
125 No signal „closed“
To change the settings:
1. On the control unit, enter:
125
2. The LCD display shows: 125:Omit > 1 OFF
3. Via the keypad, select from the following items
and press:
0
Omit >1 OFF
1
Omit >1 ON
The alarm centre does not transmit the
„closed“ signal if more than 1 zone is
locked.
(Function only with Scancom Fast
Format)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
126 Change language
To change the language used for the control unit display:
1. On the control unit, enter:
126
2. The LCD display shows: 126:Lang=English
3. Via the keypad, select from the following items
and press:
00
ENGLISH
01
ITALIAN
02
ESPANOL
03
PORT
04
NEDERL
05
FRANCAI
06
GERMAN
07
NORW.
08
SWED.
09
DANSK
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
128 External alarm
All radio transmitters are monitored via the radio
expansion unit. If a radio zone has not communicated with
the radio expansion unit for more than 2 hours then this
reports a monitoring error. The external alarm function
describes how the alarm centre reacts to this fault. To
change the settings:
1. On the control unit, enter:
128
2. The LCD display shows: 128:Full Alarm
3. Via the keypad, select from the following items
and press:
0
Full Alarm
call to central station
1
Local Alarm
Internal, ex control unit tone
2
Keypads only
3
Comms only
4
Inhibit Set
Control unit tone; the alarm centre can
not be activated until the faulty detector
reacts
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Содержание Terxon MX
Страница 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Страница 104: ...104 D...
Страница 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Страница 149: ...45 UK Entry delay group 2 202 n See 201 Entry delay group 3 203 n See 201 Entry delay group 4 204 n See 201...
Страница 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Страница 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Страница 320: ...16 NL Aansluitingen voor telefoonaansluiting RJ11 A B A1 B1 RJ11 aansluiting schroefaansluitingen voor telefoonleiding...
Страница 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Страница 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Страница 484: ...102 DK...