- 48 -
C010CC4
4 - Operations
F
irst phase - electric parameter monitoring
If the parameters measured in start up are correct, the system will proceed to the next checks.
1A)
inverter part number.
2A)
inverter serial number and firmware revision level.
3A)
E-tod :
Daily energy output.
$-tod
: Daily energy savings. Value is expressed in the set
currency.
4A)
E-tot :
Lifetime energy output since first installation .
E-par
: Partial energy output during selected period.
5A)
P-out :
Measured instant output power.
The second line of the display shows the higher of two
temperatures:
• T-inv:
inverter temperature.
• T-boost:
heatsink temperature.
6A)
Ppk:
Maximum peak power achieved since partial
counter was activated.
Ppk Day
: Maximum peak power achieved during the day.
Counter will reset when unit is powered off.
7A)
Vgrid:
Measured instant grid voltage.
Vgrid Avg
: Average grid voltage during the last 10 minutes
of operation.
8A)
Igrid:
Measured instant grid current.
Fgrid
: Measured instant grid frequency.
9A)
Vin:
input voltage value.
Iin1
: Instant input current value.
10A)
Pin:
Measured instant input power
11A)
Riso:
Measured insulation resistance.
Unlike the parameters discussed above, this is not an
instant value but a measurement taken one time during
inverter start-up
.
12A)
When all items described above test OK, the inverter
shows a corresponding message in the display top line
along with date and time in the bottom line.
Clock malfunctioning or other non function-related faults
(faults that do not affect the inverter’s ability to generate energy) will be shown in the bottom
line of the display in place of date and time.
The following error messages may be displayed instead of date and time:
•
CLOCK FAIL - indicates clock malfunction, contact service.
•
BATTERY LOW
• SET TIME - appears the first time the unit is powered up or after the battery has been
replaced.
•
FAN FAIL - contact service.
•
MEMORY FAIL - data logging malfunction; contact service.
Type OUTD
PN --------
SN -------- xxxxxx
FW rel. C.0.1.1
E-tod
0 Wh
$-tod 0.0 USA
E-tot
--------
E-par
0 KWh
P-out
0 W
T-inv
˚C
Ppk
W
Ppk Day
W
Vgrid
197
Vgrid Avg
0
Igrid
0.8 A
Fgrid 60.18 Hz
Vin
0 V
I in
0.0 A
Pin
0 W
Riso
0.0 Mohm
Ileak 73 mA
Inverter OK
Wed 17 May 11:23
1A
2A
3A
4A
5A
7A
6A
8A
10A
11A
12A
9A
Содержание PVI-3.0-TL-OUTD-S-US
Страница 1: ...ABB solar inverters Product manual PVI 3 0 3 6 3 8 4 2 TL OUTD S US A 3 0 to 4 2 kW ...
Страница 16: ... 16 3005CC2 2 Installation location ...
Страница 32: ... 32 3007CC3 3 Mounting and wiring ...
Страница 62: ... 62 C011C5 5 Troubleshooting ...
Страница 66: ... 66 C012C6 6 Maintenance ...
Страница 72: ... 72 C013C7 7 Appendix Output power with one DC section operating ...