- 17 -
3006CH3
W
all mounting
The inverter should be mounted vertically as shown in section 2.
Follow the steps on the next page for mounting the inverter.
Included in the shipping package is a mounting kit with four screws
and four wall plugs provided for mounting the metal bracket to a
concrete wall. The screws should be mounted in the four holes
present in the bracket (shown as position B at right). Use two
additional screws in the two holes shown as position A if needed to
ensure stability of the inverter.
If the installation is done on a concrete wall, the wall plugs provided
should be used and the mounting holes in the wall should have
a 10mm diameter and 75mm depth. When the wall is made of a
different material (other than concrete) the installation should be
done using adequate mounting material. ABB recommends always
using stainless steel screws.
Components included in mounting kit XAK.00060.0
1 Wall bracket shown at right - 833G7424400-G
1 Hardware bag containing:
4 - 6.3 x 70mm screws, washers, and- S x 10 anchors
4 - 6 x 10mm machine screw
1
- 6mm flat washer
1 - Red cable AWG10 - 9153G038600
1 - Black cable AWG10 - 9153G038700
1 - Torx 20 wrench 81510000077
2 - Terminal connectors 82000006439-G
3
Mounting and wiring
Содержание PVI-3.0-TL-OUTD-S-US
Страница 1: ...ABB solar inverters Product manual PVI 3 0 3 6 3 8 4 2 TL OUTD S US A 3 0 to 4 2 kW ...
Страница 16: ... 16 3005CC2 2 Installation location ...
Страница 32: ... 32 3007CC3 3 Mounting and wiring ...
Страница 62: ... 62 C011C5 5 Troubleshooting ...
Страница 66: ... 66 C012C6 6 Maintenance ...
Страница 72: ... 72 C013C7 7 Appendix Output power with one DC section operating ...