Note
Action
xx1600000193
Wipe clean the KM nut.
5
Wipe clean the o-ring in the KM nut.
6
xx1600000188
Attach the o-ring in its groove in the KM
nut.
Tip
Put a little grease on the o-ring for a better
fitting.
7
Locking liquid: Loctite 243
xx1600000192
Apply locking liquid on the threads and refit
the KM nut.
8
xx1700000970
Make sure that the dial gauge attachment
is fitted.
9
Sleeve KM nut D=152 L=220: 3HAC038174-
067
Secure the axis-2 KM nut with the Sleeve
KM nut, until the dial gauge shows 0.38
mm.
10
Continues on next page
Product manual - IRB 8700
495
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.5.7 Replacing the parallel arm
Continued
Содержание IRC5 Compact
Страница 1: ...ROBOTICS Product manual IRB 8700 ...
Страница 2: ...Trace back information Workspace R18 1 version a12 Checked in 2018 03 27 Skribenta version 5 2 025 ...
Страница 16: ...This page is intentionally left blank ...
Страница 824: ...This page is intentionally left blank ...
Страница 838: ...This page is intentionally left blank ...
Страница 840: ...This page is intentionally left blank ...
Страница 846: ......
Страница 847: ......