Note
Action
Loctite 574
xx1600000048
Apply flange sealant (Loctite 574) on the
wrist cover flange.
3
Make sure that the cable harness will be
placed in a way that it will not be damaged
when the cover is fitted.
4
Attachment screws: M8x25 8.8 (17 pcs)
Refit the wrist cover and tighten all screws
alternately and repeat once.
Note
The position of axis-4 depends on the on-
going procedure.
5
Tightening torque: 24 Nm
xx1500003100
xx1500002330
Axis Calibration is described in
with Axis Calibration method on page 805
Recalibrate the robot.
6
General calibration information is included
in section
.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page 27
.
7
302
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued