Note
Action
Tightening torque: 4 Nm.
Check that the battery is located correctly in the
battery compartment and not pinched under the
top cover.
2
Hexagon flange bolt: 3HAC060233-
006 (M6x16 stainless steel/A4-80)
Then fasten the battery cover and sealing, with
lubricated screws and washers.
Note
Do not overtighten to avoid damaging the sealing.
Washer: 3HAC058626-003 (M6 hy-
gienic. If the rubber is damaged,
replace the washer with new for
hygienic purpose.)
Anti-seize paste: 3HAC070875-002
(Molykote P1900)
xx1900000407
xx2000001006
Reconnect connector R1.MP to the base.
3
Concluding procedure
Note
Action
See
Calibrate the robot.
1
DANGER
Make sure all safety requirements are met when
performing the first test run.
2
Product manual - IRB 390
255
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the axis-4 motor
Continued
Содержание IRB 390
Страница 1: ...ROBOTICS Product manual IRB 390 ...
Страница 2: ...Trace back information Workspace 21A version a11 Checked in 2021 03 19 Skribenta version 5 4 005 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 44: ...This page is intentionally left blank ...
Страница 118: ...This page is intentionally left blank ...
Страница 330: ...This page is intentionally left blank ...
Страница 344: ......
Страница 345: ......