Note
Action
Cut the cable tie
2
Screws (3 pcs)
xx1900000753
Remove the screws that secure the SMB unit
bracket.
3
xx1900000754
Pull out the SMB unit assembly a little and discon-
nect the connectors from the SMB board:
•
R2.FB1-4, R2.FB5 (IRB 390 - 10/1300)
•
Battery cable connector R2.G.
Disconnect the battery cable by pressing
down the upper lip of the R2.G connector
to release the lock while pulling the connect-
or upwards.
4
xx1700000993
Continues on next page
164
Product manual - IRB 390
3HAC066566-001 Revision: B
© Copyright 2020 - 2021 ABB. All rights reserved.
5 Repair
5.4.3 Replacing the SMB unit
Continued