190
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
11.12 Ref2Mux (speed reference 2 selector/multiplexer)
Speed reference 2 selector:
0 = Invert1102
Invert speed ref. 1 selection; implements a change over switch together with speed ref 2
selection. E.g. if speed ref. 1 selection switch is open the switch for speed ref. 2 is closed
and vice versa.
1 = Open
switch for speed ref. 2 is fixed open, default
2 = Close
switch for speed ref 2 is fixed closed
3 = DI1
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
4 = DI2
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
5 = DI3
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
6 = DI4
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
7 = DI5
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
8 = DI6
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
9 = DI7
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
10 = DI8
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0
11 = DI9
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
12= DI10
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
13 = DI11
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
14 = MCW Bit11
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 11
15 = MCW Bit12
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 12
16 = MCW Bit13
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 13
17 = MCW Bit14
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 14
18 = MCW Bit15
1= switch is closed, speed ref 2 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 15
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Inv
er
t110
2
M
C
W
B
it
15
O
pen
-
11.13 MotPotUp (motor pot up)
With the motor pot up function, the motor speed is increased by means of the selected binary input. AccTime1
(22.01) limits the acceleration. MotPotDown (11.14) overrides MotPotUp (11.13):
0 = NotUsed default
1 = DI1
1= increase speed, 0 = hold speed
2 = DI2
1= increase speed, 0 = hold speed
3 = DI3
1= increase speed, 0 = hold speed
4 = DI4
1= increase speed, 0 = hold speed
5 = DI5
1= increase speed, 0 = hold speed
6 = DI6
1= increase speed, 0 = hold speed
7 = DI7
1= increase speed, 0 = hold speed
8 = DI8
1= increase speed, 0 = hold speed
9 = DI9
1= increase speed, 0 = hold speed, only available with digital extension board
10 = DI10
1= increase speed, 0 = hold speed, only available with digital extension board
11 = DI11
1= increase speed, 0 = hold speed, only available with digital extension board
12 = MCW Bit11
1= increase speed, 0 = hold speed, MainCtrlWord (7.01) bit 11
13 = MCW Bit12
1= increase speed, 0 = hold speed, MainCtrlWord (7.01) bit 12
14 = MCW Bit13
1= increase speed, 0 = hold speed, MainCtrlWord (7.01) bit 13
15 = MCW Bit14
1= increase speed, 0 = hold speed, MainCtrlWord (7.01) bit 14
16 = MCW Bit15
1= increase speed, 0 = hold speed, MainCtrlWord (7.01) bit 15
Note:
The speed reference is selected by means of Ref1Sel (11.03) = MotPot respectively Ref2Sel (11.06) =
MotPot.
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
M
C
W
B
it
15
No
tUs
e
d
Содержание DCS550 Series
Страница 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Страница 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...