183
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
10.07 HandAuto (Hand/Auto command)
Binary signal to switch between Hand (Local I/O) and Auto (MainCtrlWord) control. Thus the selection made
by CommandSel (10.01) is overwritten:
0 = NotUsed
1 = DI1
1 = Auto, 0 = Hand
2 = DI2
1 = Auto, 0 = Hand
3 = DI3
1 = Auto, 0 = Hand
4 = DI4
1 = Auto, 0 = Hand
5 = DI5
1 = Auto, 0 = Hand
6 = DI6
1 = Auto, 0 = Hand
7 = DI7
1 = Auto, 0 = Hand
8 = DI8
1 = Auto, 0 = Hand
9 = DI9
1 = Auto, 0 = Hand, only available with digital extension board
10 = DI10
1 = Auto, 0 = Hand, only available with digital extension board
11 = DI11
1 = Auto, 0 = Hand, only available with digital extension board
12 = MCW Bit11
1 = Auto, 0 = Hand, MainCtrlWord (7.01) bit 11
13 = MCW Bit12
1 = Auto, 0 = Hand, MainCtrlWord (7.01) bit 12
14 = MCW Bit13
1 = Auto, 0 = Hand, MainCtrlWord (7.01) bit 13
15 = MCW Bit14
1 = Auto, 0 = Hand, MainCtrlWord (7.01) bit 14
16 = MCW Bit15
1 = Auto, 0 = Hand, MainCtrlWord (7.01) bit 15
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
M
C
W
B
it
15
No
tUs
e
d
-
10.08 Off2 (Off2 command, electrical disconnect)
Binary signal for Off2 (Emergency Off / Coast Stop), UsedMCW (7.04) bit 1. For fastest reaction use fast
digital inputs DI7 or DI8:
0 = NotUsed
1 = DI1
1= no Off2, 0 = Off2 active
2 = DI2
1= no Off2, 0 = Off2 active
3 = DI3
1= no Off2, 0 = Off2 active
4 = DI4
1= no Off2, 0 = Off2 active, default
5 = DI5
1= no Off2, 0 = Off2 active
6 = DI6
1= no Off2, 0 = Off2 active
7 = DI7
1= no Off2, 0 = Off2 active
8 = DI8
1= no Off2, 0 = Off2 active
9 = DI9
1= no Off2, 0 = Off2 active, only available with digital extension board
10 = DI10
1= no Off2, 0 = Off2 active, only available with digital extension board
11 = DI11
1= no Off2, 0 = Off2 active, only available with digital extension board
12 = MCW Bit11
1= no Off2, 0 = Off2 active, MainCtrlWord (7.01) bit 11
13 = MCW Bit12
1= no Off2, 0 = Off2 active, MainCtrlWord (7.01) bit 12
14 = MCW Bit13
1= no Off2, 0 = Off2 active, MainCtrlWord (7.01) bit 13
15 = MCW Bit14
1= no Off2, 0 = Off2 active, MainCtrlWord (7.01) bit 14
16 = MCW Bit15
1= no Off2, 0 = Off2 active, MainCtrlWord (7.01) bit 15
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
M
C
W
B
it
15
DI
4
-
Содержание DCS550 Series
Страница 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Страница 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Страница 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...