Note
Action
xx2300000843
Valid for CRB 15000-10/1.52
and CRB 15000-
12/1.27
Remove the cable brackets.
3
xx2000002087
Remove the functional and protective earth cables
by removing the screw.
4
xx2000002089
Snap loose and disconnect the connectors:
•
J4/5.DC+
•
J4/5.DC-
•
J4/5.CS
•
J4/5.CP
5
Tweezers
Disconnect the connectors that belongs to the
axis-5 cabling, from the axis-4 drive board:
•
D3/4.X2
•
D3/4.DC-
•
D3/4.DC+
Use tweezers, if needed.
6
xx2000002125
Continues on next page