Disconnecting the axis-5 joint unit cabling
Note
Action
xx2000002135
Cut the cable ties.
1
xx2000002136
Remove the functional and protective earth cables
by removing the screw.
2
xx2000002137
Snap loose and disconnect the connectors:
•
J5/6.DC+
•
J5/6.DC-
•
J5/6.CS
•
J5/6.CP
3
Tweezers
Disconnect the connectors from the drive board.
•
D4/5.X1
•
D5.DC+
•
D5.DC-
•
D4/5.X4
•
D5.X2
•
D4/5.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
xx2000002138
Continues on next page
432
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.6 Replacing the axis-5 cabling
Continued