Note
Action
Move the robot to the installation site.
CAUTION
Do not leave the robot standing unfastened to
the foundation, it is not stable on its own.
6
Centering pins: DIN6325, hardened
steel Ø6x24 mm, 2 pcs .
Fit two pins to the holes in the base.
7
Make sure the robot base is correctly
fitted onto the pins.
Guide the robot gently, using the attachment
screws while lowering it into its mounting pos-
ition.
8
Screws: M10x35, 4 pcs, quality 8.8
Fit the securing screws and washers in the at-
tachment holes of the base.
9
Washers: 23/10.5/2.5 mm Steel
Tightening torque: 32 Nm ±10%
Tighten the bolts in a crosswise pattern to en-
sure that the base is not distorted.
10
Concluding procedure
Note
Action
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page 90
.
1
220
Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the base cabling
Continued
Содержание CRB 15000
Страница 1: ...ROBOTICS Product manual CRB 15000 ...
Страница 2: ...Trace back information Workspace 23B version a17 Checked in 2023 06 29 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 182: ...This page is intentionally left blank ...
Страница 200: ...This page is intentionally left blank ...
Страница 1058: ...This page is intentionally left blank ...
Страница 1076: ...This page is intentionally left blank ...
Страница 1095: ......