Screen overview
303
1SVC 440 795 M1100
Screen 3:
Screen 3 shows an example of the Number range/format tab,
especially the Scaling range and Input Format
r
Allow Digit
Selection. You can enter any value from 0.00 to 10.00 (allow
digit selection). After I1 is closed, the preset actual value SV
is transferred. After the transfer, the actual value QV jumps
to the entered SV value and counts on from there. The
maximum scaling range (10.00) is assigned to the maximum
value range (9999). The QV value thus switches to the value
9999 when 10.00 is entered and I1 is actuated.
Figure: 166:
Transfer of value with Allow digit selection
Screen 4:
Screen 4 shows an example of the Number range/format tab,
and in particular the Scaling range and Input Format
r
Fixed
Step Width. You can enter any value from 0.00 to 10.00 in
step widths of 0.50 (fixed step width). After I1 is closed, the
preset actual value SV is transferred. After the transfer, the
actual value QV jumps to the entered SV value and counts on
from there. The maximum scaling range (10.00) is assigned
to the maximum value range (9999). The QV value thus
switches to the value 9999 when 10.00 is entered and I1 is
actuated.
Figure: 167:
Transfer of value with Fixed Step Width
Value entry = 10.00
QV value = 9999
Allow digit selection
Set input
QV
(OK)
15
10.00
Allow digit selection
Set input
QV
(OK)
9999
10.00
Value entry
Transfer QV value
Step width
Set input
QV
(OK)
16
8.50
Step width
Set input
QV
(OK)
8500
8.50