Wiring with the display system
200
1SVC 440 795 M1100
Function of the high-speed incremental counter
function block
Figure: 106:
Signal diagram of high-speed incremental counter
1: Counter input channel A
2: Counter input channel B
3: Upper setpoint value
>SH
4: Preset actual value
>SV
5: Lower setpoint value
>SL
6: Counter enable
7: Accept preset actual value, coil CI..EN
1
6
7
8
9
10
11
12
2
3
4
5
A
B
C
D
E
F