Display system operation
123
1SVC 440 795 M1100
Counter function block, set counter
value (Preset)
C X SE
X=01
…
32
j
j
Counter function block, reset counter
value
C X RE
X=01
…
32
j
j
Frequency counter function block,
activate counter (enable)
CF X EN
X=01
…
04
j
j
High-speed counter function block,
direction
CH X D_
X=01
…
04
j
j
High-speed counter function block,
activate counter (enable)
CH X EN
X=01
…
04
j
j
High-speed counter function block,
set counter value (Preset)
CH X SE
X=01
…
04
j
j
High-speed counter function block,
reset counter value
CH X RE
X=01
…
04
j
j
Incremental encoder counter function
block, set counter value (Preset)
CI X SE
X=01
…
02
j
j
Incremental encoder counter function
block, activate counter (enable)
CI X EN
X=01
…
02
j
j
Incremental encoder counter function
block, reset counter value
CI X RE
X=01
…
02
j
j
Comparator function block
CP
X=01
…
32
–
j
Activate text output function block
(enable)
D X EN
X=01
…
32
j
j
Data function block, trigger coil
DB X T_
X=01
…
32
j
j
PID controller, activate
DC X EN
X=01
…
32
j
j
PID controller, activate P component
DC X EP
X=01
…
32
j
j
PID controller, activate I component
DC X EI
X=01
…
32
j
j
PID controller, activate D component
DC X ED
X=01
…
32
j
j
PID controller, accept manual
manipulated variable
DC X SE
X=01
…
32
j
j
Activate signal smoothing filter
FT X EN
X=01
…
32
j
j
Relay/function block