![ABB ACS850-04 series Скачать руководство пользователя страница 265](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228265.webp)
Fault tracing 265
2043
STALL
(0x7121)
Programmable fault:
Motor is operating in stall
region because of e.g.
excessive load or insufficient
motor power.
Check motor load and drive ratings.
Check fault function parameters.
2044
LCURVE
(0x2312)
Programmable fault:
/
Overload or underload limit
has been exceeded.
Check the settings of the parameters in
group
2045
LCURVE PAR
(0x6320)
The load curve has been
incorrectly or inconsistently
defined.
Check the settings of the parameters in
group
2046
FLUX REF PAR
(0x6320)
The
U/f
(voltage/frequency)
curve has been incorrectly or
inconsistently defined.
Check the settings of the parameters in
group
.
2047
SPEED FEEDBACK
(0x8480)
No speed feedback is
received.
Check the settings of the parameters in
group
Check encoder installation. See the
description of fault
for more
information.
2048
OPTION COMM
LOSS
(0x7000)
Communication between drive
and option module (FEN-xx
and/or FIO-xx) is lost.
Check that option modules are properly
connected to Slot 1 and (or) Slot 2.
Check that option modules or Slot 1/2
connectors are not damaged. To
determine whether module or connector
is damaged: Test each module
individually in Slot 1 and Slot 2.
2049
MOTTEMPAL2
(0x4313)
Programmable fault:
Estimated motor temperature
(based on motor thermal
model) has exceeded alarm
limit defined by parameter
.
Check motor ratings and load.
Let motor cool down. Ensure proper
motor cooling: Check cooling fan, clean
cooling surfaces, etc.
Check value of alarm limit.
Check motor thermal model settings
(parameters
).
Measured motor temperature
has exceeded alarm limit
defined by parameter
.
Check that actual number of sensors
corresponds to value set by parameter
.
Check motor ratings and load.
Let motor cool down. Ensure proper
motor cooling: Check cooling fan, clean
cooling surfaces, etc.
Check value of alarm limit.
2050
IGBTOLALARM
(0x5482)
Excessive IGBT junction to
case temperature. This alarm
protects the IGBT(s) and can
be activated by a short circuit
in the motor cable.
Check motor cable.
2051
IGBTTEMPALARM
(0x4210)
Drive IGBT temperature is
excessive.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Code
Alarm
(fieldbus code)
Cause
What to do
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...