49.05
Data storage5
Data storage parameter 5.
-2147483647 …
2147483647
32-bit data.
1 = 1
49.06
Data storage6
Data storage parameter 6.
-2147483647 …
2147483647
32-bit data.
1 = 1
49.07
Data storage7
Data storage parameter 7.
-2147483647 …
2147483647
32-bit data.
1 = 1
49.08
Data storage8
Data storage parameter 8.
-2147483647 …
2147483647
32-bit data.
1 = 1
50
50 Fieldbus
Settings for configuration of communication via a fieldbus
adapter.
50.01
Fba enable
Enables communication between the drive and fieldbus
adapter.
Disable
Communication between the drive and fieldbus adapter
disabled.
0
Enable
Communication between the drive and fieldbus adapter
enabled.
1
50.02
Comm loss func
Selects how the drive reacts in a fieldbus communication
break. The time delay is defined by parameter
No
Communication break detection disabled.
0
Fault
Communication break detection active. Upon a
communication break, the drive trips on fault FIELDBUS
COMM and coasts to stop.
1
Spd ref Safe
Communication break detection active. Upon a
communication break, the drive generates alarm FIELDBUS
COMM and sets the speed to the value defined by parameter
.
WARNING
! Make sure that it is safe to continue
operation in case of a communication break.
2
Last speed
Communication break detection active. The drive generates
alarm FIELDBUS COMM and freezes the speed to the level
the drive was operating at. The speed is determined by the
average speed over the previous 10 seconds.
WARNING
! Make sure that it is safe to continue
operation in case of a communication break.
3
50.03
Comm loss t out
Defines the time delay before the action defined by parameter
is taken. Time count starts when the
link fails to update the message.
0.3 … 6553.5 s
Time delay.
10 = 1 s
50.04
Fba ref1 modesel
Selects the fieldbus reference FBA REF1 scaling and the
actual value, which is sent to the fieldbus (FBA ACT1).
No.
Name/Value
Description
FbEq
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...