82 Application macros
Factory macro
The Factory macro is suited to relatively straightforward speed control applications
such as conveyors, pumps and fans, and test benches.
In external control, the control location is EXT1. The drive is speed-controlled; the
reference signal is connected to analog input AI1. The sign of the reference
determines the running direction. The start/stop commands are given through digital
input DI1. Faults are reset through DI3.
The default parameter settings for the Factory macro are listed in chapter
(page