![ABB ACS850-04 series Скачать руководство пользователя страница 226](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228226.webp)
226 Parameters
91.04
Pos data bits
Defines the number of bits used within one revolution. Used
with serial interfaces, i.e. when parameter
.
0…32
Number of bits. For example, 32768 positions per revolution
corresponds to 15 bits.
1 = 1
91.05
Refmark ena
Enables the encoder zero pulse (if used). Zero pulse can be
used for position latching.
Note:
With serial interfaces (i.e. when parameter
),
zero pulse must be disabled.
False
Zero pulse disabled.
0
True
Zero pulse enabled.
1
91.10
Hiperface parity
Defines the use of parity and stop bits for HIPERFACE
encoder (i.e. when parameter
setting is
). Typically, this parameter does not need to be set.
Odd
Odd parity indication bit, one stop bit.
0
Even
Even parity indication bit, one stop bit.
1
91.11
Hiperf baudrate
Defines the transfer rate of the link for HIPERFACE encoder
(i.e. when parameter
). Typically, this parameter does not need to be set.
4800
4800 bit/s
0
9600
9600 bit/s
1
19200
19200 bit/s
2
38400
38400 bit/s
3
91.12
Hiperf node addr
Defines the node address for HIPERFACE encoder (i.e. when
parameter
).
Typically, this parameter does not need to be set.
0…255
HIPERFACE encoder node address.
1 = 1
91.20
SSI clock cycles
Defines the length of the SSI message. The length is defined
as the number of clock cycles. The number of cycles can be
calculated by adding 1 to the number of bits in an SSI
message frame.
Used with SSI encoders, i.e. when parameter
.
2…127
Length of SSI message.
1 = 1
91.21
SSI position msb
Defines the location of the MSB (most significant bit) of the
position data within an SSI message.
Used with SSI encoders, i.e. when parameter
.
1…126
Location of MSB (bit number) in SSI position data.
1 = 1
91.22
SSI revol msb
Defines the location of the MSB (most significant bit) of the
revolution count within an SSI message.
Used with SSI encoders, i.e. when parameter
.
1…126
Location of MSB (bit number) in SSI revolution count.
1 = 1
91.23
SSI data format
Selects the data format for SSI encoder (i.e. when parameter
binary
Binary data format.
0
gray
Gray data format.
1
No.
Name/Value
Description
FbEq
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...