![ABB ACS850-04 series Скачать руководство пользователя страница 272](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228272.webp)
272 Fault tracing
0039
ENCODER1
(0x7301)
Encoder 1 feedback fault
If fault appears during first start-up before
encoder feedback is used:
- Check cable between encoder and
encoder interface module (FEN-xx) and
order of connector signal wires at both
ends of cable.
If fault appears after encoder feedback
has already been used or during drive
run:
- Check that encoder connection wiring
or encoder is not damaged.
- Check that encoder interface module
(FEN-xx) connection or module is not
damaged.
- Check earthings (when disturbances
are detected in communication between
encoder interface module and encoder).
For more information on encoders, see
parameter groups
,
and
.
0040
ENCODER 2
(0x7381)
Encoder 2 feedback fault.
0045
FIELDBUS COMM
(0x7510)
Programmable fault:
Cyclical communication
between drive and fieldbus
adapter module or between
PLC and fieldbus adapter
module is lost.
Check status of fieldbus communication.
See appropriate User’s Manual of
fieldbus adapter module.
Check settings of parameter group
Check cable connections.
Check if communication master is able to
communicate.
0046
FB MAPPING FILE
(0x6306)
Drive internal fault
Contact your local ABB representative.
0047
MOTOR OVERTEMP
(0x4310)
Programmable fault:
Estimated motor temperature
(based on motor thermal
model) has exceeded fault limit
defined by parameter
Check motor ratings and load.
Let motor cool down. Ensure proper
motor cooling: Check cooling fan, clean
cooling surfaces, etc.
Check value of fault limit.
Check motor thermal model settings
(parameters
…
Measured motor temperature
has exceeded fault limit
defined by parameter
Check that actual number of sensors
corresponds to value set by parameter
Check motor ratings and load.
Let motor cool down. Ensure proper
motor cooling: Check cooling fan, clean
cooling surfaces, etc.
Check value of fault limit.
0049
AI SUPERVISION
(0x8110)
Programmable fault:
An analogue input has reached
limit defined by parameter
Check analogue input source and
connections.
Check analogue input minimum and
maximum limit settings.
Code
Fault
(fieldbus code)
Cause
What to do
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...