84 CR12/CT12, VR12/VP12 UEFI Firmware User's Guide
Publication No. UGCR12V051E Rev. A.0
6.3 O/S Watchdog Timer
The optimal default is
Disabled
.
The O/S Watchdog Timer is designed to determine the successful operating system
boot and initialization.
Feature can be enabled in Setup; hence special Management Software is required to
shut off timer after the OS loads.
6.4 O/S Wtd Timer Timeout
The optimal default is
10 minutes
.
The timer can be set from 5 minutes to approximately 20 minutes
6.5 O/S Wtd Timer Policy
The optimal default is
Reset
.
If the O/S Watchdog timer is not disabled by special Management Software after OS
load, the system generates a
Reset, Power Down
or
Do Nothing
.
6.6 BMC Self Test Log
The BMC self test reporting into UEFI firmware can be managed here.
Select the BMC self test log tab from the Server Mgmt screen to enter BMC self test log
screen.