Overheat Power-off Process
The module overheat power-off process is as follows:
1
When any chassis temperature sensor detects an internal chassis
operating temperature of 45 °C (113 °F) or higher, power management
issues warning traps that inform the user that an overheat condition may
soon exist. The system generates warning traps every 30 seconds
(approximately) at this point.
2
When internal chassis operating temperature reaches 60 °C
(140 °F), power management power-disables
selected
modules installed
within the affected overheat management area to reduce the 5-volt
power consumption by at least 50 watts.
Selected modules in the overheat management area power off, in order,
starting with modules that have the lowest power class setting.
This reduction of power consumption should provide a 2 °C
drop in
temperature per slot at the temperature sensor for the overheat
management area. The system generates overheat traps every 10 seconds
(approximately).
3
If two or more modules in the affected overheat management area have
the
same
power class, they power off from highest slot number to lowest
slot number.
4
Switch fabric modules and interface modules continue to power off until
all modules in the affected overheat management area have powered off
or until you resolve the overheating condition. Modules with a power
class setting of 10 continue to run.
5
Chassis temperature is allowed to stabilize for 15 minutes before further
action is taken.
6
If chassis temperature is not at or below the established overheat
threshold after 15 minutes have elapsed,
all
modules are powered off.
Modules do not power on again until you correct the overheat condition.
Содержание 4007
Страница 1: ...http www 3com com Switch 4007 Implementation Guide Release 3 0 5 Part No 10013673 Published May 2000 ...
Страница 36: ...36 ABOUT THIS GUIDE ...
Страница 37: ...I UNDERSTANDING YOUR SWITCH 4007 SYSTEM Chapter 1 Configuration Overview ...
Страница 38: ......
Страница 50: ...50 CHAPTER 1 CONFIGURATION OVERVIEW ...
Страница 52: ......
Страница 70: ...70 CHAPTER 3 INSTALLING MANAGEMENT MODULES ...
Страница 110: ...110 CHAPTER 4 CONFIGURING AND USING EME OPTIONS ...
Страница 130: ...130 CHAPTER 5 MANAGING THE CHASSIS POWER AND TEMPERATURE ...
Страница 222: ...222 CHAPTER 11 IP MULTICAST FILTERING WITH IGMP ...
Страница 240: ...240 CHAPTER 13 RESILIENT LINKS ...
Страница 304: ...304 CHAPTER 14 VIRTUAL LANS VLANS ...
Страница 350: ...350 CHAPTER 15 PACKET FILTERING ...
Страница 506: ...506 CHAPTER 19 OPEN SHORTEST PATH FIRST OSPF ROUTING ...
Страница 534: ...534 CHAPTER 20 IPX ROUTING ...
Страница 612: ...612 CHAPTER 22 QOS AND RSVP ...
Страница 656: ...656 CHAPTER 23 DEVICE MONITORING ...
Страница 657: ...IV REFERENCE Appendix A Technical Support Index ...
Страница 658: ......
Страница 664: ......