Managing Power in
the Chassis
The chassis provides a fault-tolerant, managed, intelligent power supply
subsystem. This subsystem supports:
■
Load-sharing power supplies
■
High power availability
■
EME-based power verification features that are designed to ensure
optimal performance
Intelligent Power
Subsystem Features
The intelligent power subsystem includes the following features:
■
Load-sharing power supplies
— Provides evenly distributed power
consumption among all installed power supplies. Chassis activity
disruption is minimized if a power supply fails because there is no
changeover (and hence, no changeover interval).
■
Front-loading and rear-loading accessibility
— Provides easy
access for upgrades. As your power needs increase over time, it is easy
to upgrade by adding a power supply into the rear of the 7-slot
chassis. Because power supplies are modular and plug into the
backplane, replacing a faulty power supply is a quick procedure.
■
High power capacity
— The power mode and the amount of power
available determine the current power limit. The actual power that is
delivered depends on whether you are running in non-fault-tolerant
mode or in fault-tolerant mode.
(For detailed information about power supply capacity, see “Power
Non-Fault-Tolerant Mode” and “Power Fault-Tolerant Mode” later in
this chapter.)
If a power supply fails while the chassis is running in fault-tolerant
mode, still-functioning power supplies provide all of the power
necessary to keep installed modules and the chassis running.
■
Software-driven, power management
— The EME polls each
switch fabric module and interface module that is installed in the
chassis to confirm that enough power is available for new module to
power on. If available power is:
■
Adequate
— The new module powers on.
■
Inadequate
— The new module does not power on. System
overload is avoided.
Содержание 4007
Страница 1: ...http www 3com com Switch 4007 Implementation Guide Release 3 0 5 Part No 10013673 Published May 2000 ...
Страница 36: ...36 ABOUT THIS GUIDE ...
Страница 37: ...I UNDERSTANDING YOUR SWITCH 4007 SYSTEM Chapter 1 Configuration Overview ...
Страница 38: ......
Страница 50: ...50 CHAPTER 1 CONFIGURATION OVERVIEW ...
Страница 52: ......
Страница 70: ...70 CHAPTER 3 INSTALLING MANAGEMENT MODULES ...
Страница 110: ...110 CHAPTER 4 CONFIGURING AND USING EME OPTIONS ...
Страница 130: ...130 CHAPTER 5 MANAGING THE CHASSIS POWER AND TEMPERATURE ...
Страница 222: ...222 CHAPTER 11 IP MULTICAST FILTERING WITH IGMP ...
Страница 240: ...240 CHAPTER 13 RESILIENT LINKS ...
Страница 304: ...304 CHAPTER 14 VIRTUAL LANS VLANS ...
Страница 350: ...350 CHAPTER 15 PACKET FILTERING ...
Страница 506: ...506 CHAPTER 19 OPEN SHORTEST PATH FIRST OSPF ROUTING ...
Страница 534: ...534 CHAPTER 20 IPX ROUTING ...
Страница 612: ...612 CHAPTER 22 QOS AND RSVP ...
Страница 656: ...656 CHAPTER 23 DEVICE MONITORING ...
Страница 657: ...IV REFERENCE Appendix A Technical Support Index ...
Страница 658: ......
Страница 664: ......