1-11
Item
Description
CDP Operating Mode
Set the CDP compatibility of LLDP. Available options
include:
z
Disable: Neither sends nor receives CDPDUs.
z
TxRx: Sends and receives CDPDUs
To enable LLDP to be compatible with CDP on the port,
you must enable CDP compatibility on the Global Setup
tab and set the CDP operating mode on the port to TxRx.
LLDP Polling Interval
Enable LLDP polling and set the polling interval.
If no polling interval is set, LLDP polling is disabled.
With the polling mechanism, LLDP periodically detects
local configuration changes. If a configuration change is
detected, an LLDPDU is sent to inform the LLDP
neighbors of the change.
LLDP Trapping
Set the enable status of the LLDP trapping function on the
port or ports.
LLDP trapping is used to report to the network
management station critical events such as new neighbor
devices detected and link failures.
To avoid excessive traps from being sent when topology is
instable, you can tune the minimum trap transit interval on
the Global Setup tab.
Port Description
Select to include the port description TLV in transmitted
LLDPDUs.
System Capabilities
Select to include the system capabilities TLV in
transmitted LLDPDUs.
System Description
Select to include the system description TLV in transmitted
LLDPDUs.
System Name
Select to include the system name TLV in transmitted
LLDPDUs.
Base TLV
Settings
Management
Address
Select to include the management address TLV in
transmitted LLDPDUs and in addition, set the
management address and its format (a numeric or
character string in the TLV).
If no management address is specified, the main IP
address of the lowest VLAN carried on the port is used. If
no main IP address is assigned to the VLAN, 127.0.0.1 is
used.
Port VLAN ID
Select to include the PVID TLV in transmitted LLDPDUs.
Protocol VLAN ID
Select to include port and protocol VLAN ID TLVs in
transmitted LLDPDUs and specify the VLAN IDs to be
advertised.
If no VLAN is specified, the lowest protocol VLAN ID is
transmitted.
DOT1 TLV
Setting
VLAN Name
Select to include VLAN name TLVs in transmitted
LLDPDUs and specify the VLAN IDs to be advertised.
If no VLAN is specified, the lowest VLAN carried on the
port is advertised.
Содержание 2928 - Baseline Plus Switch PWR
Страница 92: ...1 9 Figure 1 7 Display the rate settings of ports ...
Страница 105: ...1 4 Figure 1 3 Switch to the management level ...
Страница 106: ...i Table of Contents 1 Loopback Test Configuration 1 1 Overview 1 1 Loopback Operation 1 1 Configuration Guidelines 1 2 ...
Страница 109: ...i Table of Contents 1 VCT 1 1 Overview 1 1 Testing Cable Status 1 1 ...
Страница 114: ...1 2 Figure 1 2 Port traffic statistics ...
Страница 138: ...i Table of Contents 1 Energy Saving Configuration 1 1 Overview 1 1 Configuring Energy Saving on a Port 1 1 ...
Страница 159: ...i Table of Contents 1 Interface Statistics 1 1 Overview 1 1 Displaying Interface Statistics 1 1 ...
Страница 279: ...1 28 Figure 1 26 The Port Setup tab ...
Страница 331: ...i Table of Contents 1 Service Management 1 1 Overview 1 1 Configuring Service Management 1 2 ...