2N Access Unit Configuration Manual
47
/
134
•
•
•
•
•
•
•
•
card, etc.), the access module will be blocked for 30 seconds even if authentication is
valid.
License Plate Recognition
– choose the scenario after the license plate is recognized.
Refer to the manual for function details.
Service cards are two common cards that are dedicated to this particular purpose by you. Be
sure to complete their IDs in the Plus card ID and Minus card ID items in this section. The count
of access card ID characters is given by the card type and is variable. However, it holds true that
all cards of the same type have equally long IDs.
The plus/minus cards are used for user card administration. When a plus card is tapped on the
card reader, any other tapped card is added to the Directory list as a new user with an access
card assigned. The user !Visitor #card_ID is automatically created in the device. When a minus
card is tapped on the card reader, any other tapped card and its user are deleted from the
Directory list. The RFID card record will be cancelled and access via this card will be blocked.
Plus card ID
– enter the service card ID for adding cards to the Installed cards: a sequence
of 6 to 32 characters including 0–9, A–F.
Minus card ID
– enter the service card ID for removing cards from the Installed cards: a
sequence of 6 to 32 characters including 0–9, A–F.
Anti-Passback is a security function preventing users to use their access cards or other
identifiers to re-enter an area without leaving it before (i.e. preventing users from sharing
cards).
Mode
– enable/disable the Anti-Passback mode:
Off
– the function is Off by default allowing the user to use the access card or
another identifier to re-enter an area without leaving it before.
Soft
– the user is allowed to use the access card or another identifier to re-enter an
area without leaving it before. A new
AccessTaken
record is made in Status / Events.
Hard
– the user is not allowed to use the access card or another identifier to re-enter
an area without leaving it before. A new
UserRejected
record is made in Status /
Events.
Time limitation
– select an Anti-Passback timeout during which the user cannot re-enter
an area using the given authentication method (card, code, etc.) in the same direction.
Содержание Access Unit
Страница 1: ...2N Access Unit Configuration Manual v 2 34 www 2n com ...
Страница 17: ...2N Access Unit Configuration Manual 17 134 ...
Страница 97: ...2N Access Unit Configuration Manual 97 134 ...
Страница 127: ...2N Access Unit Configuration Manual 127 134 General overview of local syslog messages ...
Страница 134: ...Konfigurační manuál 2N Access Unit 134 134 ...