Module Name
– set the module name for input/output specification in the SetOutput,
GetInput and InputChanged objects in the
2N
Automation
.
Door
– set the reader direction (Arrival, Departure) for the Attendance system purposes.
Associated Switch
– set the switch to be activated after user authentication via this
module. If you set Door Lock Switch, the authentication rules specified in Hardware / Door
will be used.
Received Code Format
– set the format for the codes to be received (Wiegand 26, 32, 37
and RAW).
Output Wiegand Group
– assign the output Wiegand to a group to which the codes from
the connected card readers or Wiegand inputs can be resent.
Transmitted Code Format
– set the format for the codes to be transmitted (26-bit, 32-bit,
37-bit and RAW format, 35-bit, Corp. 1000, 48-bit, Corp. 1000 and Auto).
Change Facility Code
– set the first code part via Wiegand. This applies to Wiegand OUT
for 26-bit code format. Contact your security system supplier to know if the Facility Code is
requested.
Facility Code
– define the 2N IP device location in the security system. Enter a decimal
value for the location (0–255).