Switch Enabled
–
enable/disable the switch globally. When disabled, the switch cannot
be activated by any of the available codes (including user switch codes), by quick dial
button.
Switch mode
–
set the monostable/bistable mode for the switch. The switch is switched
off after a timeout in the monostable mode and switched on with the first activation and
off with the next activation in the bistable mode.
Switch-on duration
–
set the switch-on time for a monostable switch. This value is not
applied in the bistable mode.
Controlled output
–
assign an electric output to the switch.
Choose one of the available
intercom outputs: relay, power output, extender output. If you select
None
, the switch will
not control any electric output but can control external equipment via HTTP commands.
Output type
–
if you use the
2N
®
IP Intercom - Security Relay
module, set the output
type to
Security
. In the
Security
mode, the output works in the inverse mode, i.e. remains
closed and controls the
2N
®
IP Intercom - Security Relay
module using a specific pulse
sequence. If you use the inverse mode (i.e. the door is locked when voltage is applied), set
the
inverse
output type. In case multiple switches are set to the same output but different
output types, the following priority will be applied: 1. security, 2. inverse, 3. normal.
•
Info
A switch activation value higher than 1 s can be set for the
security
output type. A
value equal to or higher than 0.1 s can be set for the
normal
and
inverse
output
types.
Содержание Access Unit
Страница 1: ...2N Access Unit Configuration Manual v 2 34 www 2n com ...
Страница 17: ...2N Access Unit Configuration Manual 17 134 ...
Страница 97: ...2N Access Unit Configuration Manual 97 134 ...
Страница 127: ...2N Access Unit Configuration Manual 127 134 General overview of local syslog messages ...
Страница 134: ...Konfigurační manuál 2N Access Unit 134 134 ...