2N Access Unit Configuration Manual
46
/
134
•
•
•
•
•
•
Zonal code
– enable the zonal code for the time profile and authentication combination in
this row. You can use the zonal code instead of the user PIN.
Zonal code
– enter the switch numeric zonal code consisting of two characters at least.
However, four characters at least are recommended.
Authentication signalling
– choose the way of signalling a used card or another identifier.
The options are Only LED (light signalling) or LED + Audio (light and acoustic signalling)
whenever a card or another identifier has been applied (both invalid – denying beep, and
valid – short beep). A distinct acoustic manifestation is only heard when an invalid card or
another identifier has been used. In the case of a valid access, the acoustic signal of the
switch is typically played making the short valid authentication beep almost inaudible. For
switch sound settings refer to
Virtual card to Wiegand
– select a group of Wiegand outputs to which the Virtual user
card No. shall be sent after successful authentication. Can be combined with any
authentication method, including codes, fingerprints, etc.
Silent alarm enabled
– a virtual code higher by 1 than the access code is assigned to each
access code and used for silent alarm activation. For example, if the access code is 0000,
then the silent alarm activation code is 0001. It means, for instance, that silent alarm is
0000 for access code 9999 and so on. Set the silent alarm action in the Automation section.
Limit failed access attempts
– enable the maximum count of unsuccessful
authentication attempts. After five unsuccessful attempts (wrong numeric code, invalid
•
Caution
If the time profile is unset, the authentication mode is ignored on the given row.
•
Caution
In case the user authenticates itself and activates the silent alarm that is
deactivated, the user access will be denied and the alarm will not be activated.
Содержание Access Unit
Страница 1: ...2N Access Unit Configuration Manual v 2 34 www 2n com ...
Страница 17: ...2N Access Unit Configuration Manual 17 134 ...
Страница 97: ...2N Access Unit Configuration Manual 97 134 ...
Страница 127: ...2N Access Unit Configuration Manual 127 134 General overview of local syslog messages ...
Страница 134: ...Konfigurační manuál 2N Access Unit 134 134 ...