5.3.2 Door
Door
Assigned switch
– select a switch for the electromagnetic door lock control.
The switch
state controls the door unlocking signalling (green door symbol, green LED).
Assigned input
– define one (or none) of the logical inputs for open door detection.
Input Mode
– set the active input mode (polarity). Non Inverted / Inverted.
Unauthorised door open detection
– detect if the door is open when switch has been
locked.
Door open too long detection
– door open too long detection.
Maximum door open time
– maximum permitted door open duration in seconds.