Hydraulic system
The system consists of the inner and outer circuit.
The source of pressurized oil is a gear pump.
Oil is drawn from the common filling of the gearbox and final drive housing.
Hydraulic pump
Control elements placement
Outer hydraulic circuit
Connecting and disconnecting quick-couplers
When connecting and disconnecting the quick-couplers pay increased attention with regard to
the residual oil that remains in the socket or on the plug of the quick-coupler. For environmental
reasons after every disconnection of quick-couplers this residual oil must be removed with any
textile material.
The hydraulic pump cannot be disengaged. When the
engine is running, the pump is in operation.
The pressure generated in the hydraulic system by the
hydraulic pump is limited by a relief valve to 20 MPa.
Pump type
Delivered quantity
URD 25/10.90V
69 l/min
F_02_113a
Control panel is placed on the right rear mudguard.
1
.
Electrohydraulics control
2
.
External hydraulic circuit control
C15N023
The outer circuit supplies pressurized oil to hydraulic
implements connected to the outer outlets of the hydraulic
system terminated with quick-couplers.
The sockets of the rear (A) as well as front (B) quick-
couplers have the inner diameter of 12.5 mm and comply
with the international ISO 5675 standard.
C15N024
HYDRAULIC SYSTEM
113
Summary of Contents for Forterra CL 100
Page 1: ...OPERATOR S MANUAL FORTERRA CL 1 2015 100 110 Tractor is Zetor Since 1946 120 130 140...
Page 3: ...2...
Page 11: ...NOTES 10...
Page 23: ...NOTES 22...
Page 45: ...NOTES 44...
Page 97: ...NOTES 96...
Page 103: ...NOTES 102...
Page 119: ...NOTES 118...
Page 133: ...NOTES 132...
Page 139: ...NOTES 138...
Page 145: ...NOTES 144...
Page 153: ...NOTES 152...
Page 196: ...NOTES 195...