Indication of DPF and SCR errors on the display of the instrument panel
type of
indication
amount of
urea in
the tank
urea signal lamp
display -
prompt to
refill urea
defect
signal
lamp
acoustic
signal
reduction of power
and limitation of
engine revolutions
signal
lamp
display
type
1st degree
of warning
less than
20%
orange
signal
lamp
activated
short-time
display
(3 s)
1 x 1 s
2nd degree
of warning
less than
15%
orange
signal
lamp
flashes
(0.5 Hz)
short-time
display
(3 s)
1 x 1 s
3rd degree
of warning
less than
10%
orange
signal
lamp
flashes
(0.5 Hz)
Continuous
display
(The prompt
disappears
after
pressing
any button
on the
instrument
panel.)
2 x 3 s
1st degree
of limitation
less than
5%
orange
signal
lamp
flashes
(1 Hz)
Continuous
display
(The prompt
disappears
after
pressing
any button
on the
instrument
panel.)
2 x 3 s
reduction of power
by 25%
2nd degree
of limitation
less than
3%
red signal
lamp
flashes
(2 Hz)
Continuous
display
2 x 3 s
reduction of power
by 50%, limitation of
max. engine
revolutions to ca.
1,250 rpm)
Error messages with the signal lamps and acoustic signal
are accompanied by indication on the display of the
instrument panel.
1 - The symbol of the defect significance.
2 - Node of the tractor where the defect appeared.
3 - Main display field - defect code.
4 - Secondary display field - defect specification.
5 - Service symbol.
Note:
More information in chapter Instrument Panel
S15N044
SYSTEM OF ADDITIONAL TREATMENT OF EXHAUST GASES
70
Summary of Contents for Forterra CL 100
Page 1: ...OPERATOR S MANUAL FORTERRA CL 1 2015 100 110 Tractor is Zetor Since 1946 120 130 140...
Page 3: ...2...
Page 11: ...NOTES 10...
Page 23: ...NOTES 22...
Page 45: ...NOTES 44...
Page 97: ...NOTES 96...
Page 103: ...NOTES 102...
Page 119: ...NOTES 118...
Page 133: ...NOTES 132...
Page 139: ...NOTES 138...
Page 145: ...NOTES 144...
Page 153: ...NOTES 152...
Page 196: ...NOTES 195...