ZAHD, ZAEHD 150/200-155/175
Cable routing
35
www.zepro.com
Image 57. Calculation of minimum conductor cross sectional area
5.2
Battery maintenance
When storing for longer than 1 week, you are recommended to disconnect the lift from the battery via the main
switch or by releasing the lift’s main fuse, in order to reduce the risk of the battery discharging. The length of
time the vehicle can be stored without the battery’s charge level becoming too low depends on the condition of
the battery, the charge level before storage and how much power the vehicle’s other components take from the
battery. After a period of storage, the battery must always be charged fully before operating the lift.
When installing the lift and when carrying out service and repair work, when the lift is operated repeatedly
without the vehicle being started and used, the battery charger must be used between operations to main-
tain the battery’s charge level.
NOTE!
The battery charger must not be connected when operating the lift. Risk of damage.
NOTE!
Ensure that the lift has access
to the minimum recommended
power capacity (I
min
). Some
vehicles have restrictions
regarding the amount of power
the lift can access from the
existing battery.
-
+
-
+
L
L
U
min
I
min
I
min
U
min
5.3
Maximum power consumption
7050
12 volt
24 volt
Pump - Motor unit
245 A
135 A
Magnet (hydraulic unit)
4,2 A
2,1 A
Magnet (electric safety valve)
1,5 A
0,75 A
Solenoid
1,5 A
0,85 A
Minimum recommended cable area
(apply copper cable, plus- and minuscable)
Control cable
1,5 mm
2
1,5 mm
2
Main cable, L < 8m
35 mm
2
35 mm
2
Main cable, L = 8 - 15m
50 mm
2
35 mm
2
Main cable, L > 15m
-
50 mm
2
Battery
Min.
capacity
, I
min
180 Ah
170 Ah
Min. voltage, U
min
(At lift)
9 Volt
18 Volt
ZAHD, ZAEHD 150/200-155/175 (200 bar)
Summary of Contents for ZAHD 150/200
Page 2: ......