ZAHD, ZAEHD 150/200-155/175
Installation
31
www.zepro.com
4.7.3
Tail lift with angle sensor IFM for autotilt
1. Install the angle sensor on the platform using the nuts, bolts and washers supplied and attach the cable
using cable time; see Image 50
2. Route the cables and secure with cable ties.
Connection is described later in section
6.
Image 50. Installing an angle sensor for auto tilt
Bracket on the platform
Autotilt angle setting
By default, the autotilt angle is set to 0°. If necessary, the position
of the angle sensor (autotilt angle) can be adjusted.
1. Loosen the two screws without removing them, see Image 51.
2. Adjust the position of the angle sensor to the desired angle,
see
Image 51
.
3. Retighten the screws.
Image 51. Adjusting the autotilt angle