34
Cable routing
www.zepro.com
5
Cable routing
5.1
General
Image 55. Protect the cable against sharp edges and use cable grommets
Image 56. Always use shrink hose over the cable connection when fitting cable terminals
IMPORTANT!
In order to ensure a high degree of reliability for many years to come, it is important that components such as batteries,
chargers, main current and earth cables, fuses and main switches are dimensioned correctly and assembled with great accuracy.
Insufficient battery power can permanently damage the electrical components in the tail lift (solenoid, electric motor, solenoid
valves, relay board/control board and more.)
Insufficient main power and/or ground cable area may result in overheating, poor performance of the electrical system and
shortened life expectancy of the main electrical components.
Earthing must not be made to anything other than the negative terminal of the battery. Risk of material damage.
Always install a shrink hose over the cable connection when installing cable terminals.
Pay attention and be careful during all cable routing to ensure longer cable life and reduce the risk of unnecessary downtime:
•
Cables must not be clamped to brake lines or the vehicle’s normal electrical system.
•
The cable must be protected by rubber grommets when it passes through beams or walls.
•
Cables must be installed sufficiently far from, or be protected against, sharp edges so they cannot chafe or otherwise
sustain damage that could lead to a short-circuit and cable fires.
•
Take care not to bend cables to too tight a radius as this can cause damage.
7050
12 volt
24 volt
Pump - Motor unit
245 A
135 A
Magnet (hydraulic unit)
4,2 A
2,1 A
Magnet (electric safety valve)
1,5 A
0,75 A
Solenoid
1,5 A
0,85 A
Minimum recommended cable area
(apply copper cable, plus- and minuscable)
Control cable
1,5 mm
2
1,5 mm
2
Main cable, L < 8m
35 mm
2
35 mm
2
Main cable, L = 8 - 15m
50 mm
2
35 mm
2
Main cable, L > 15m
-
50 mm
2
Battery
Min.
capacity
, I
min
180 Ah
170 Ah
Min. voltage, U
min
(At lift)
9 Volt
18 Volt