![background image](http://html1.mh-extra.com/html/zeiss/directfrap/directfrap_operating-manual_3316166034.webp)
INSTRUMENT DESCRIPTION
Carl Zeiss
Technical Data
DirectFRAP
34
423635-9001-701
05/2014
Operating data
DirectFRAP overall system:
Radio interference suppression ....................................................... in compliance with EN 55011 Class A
Noise immunity ................................................................................. in compliance with DIN EN 61326-1
Laser Bench Rack/Rack 3F:
Environment for use ........................................................................................................... Closed rooms
Protection class ..................................................................................................................................... I
Ingress protection rating .................................................................................................................. IP 20
Overvoltage category............................................................................................................................. II
Line voltage range ..................................................................................... 100 V AC to 230 V AC ±10 %
Change of line voltage is not required!
Line frequency........................................................................................................................... 50/60 Hz
Power consumption ........................................................................................................... max. 300 VA
Laser Bench Tower coupling module:
Environment for use ........................................................................................................... Closed rooms
Protection class ..................................................................................................................................... I
Ingress protection rating .................................................................................................................. IP 20
Overvoltage category............................................................................................................................. II
Line voltage range ..................................................................................... 100 V AC to 230 V AC ±10 %
Line frequency........................................................................................................................... 50/60 Hz
Change of line voltage is not required!
Power consumption ........................................................................................................... max. 150 VA
Fuses ......................................................................................................................... 2x T 4.0 A/H/250 V
................................................................................................................................. 1x T 1.0 A/H/250 V
Laser Bench Tower:
Environment for use ........................................................................................................... Closed rooms
Protection class ..................................................................................................................................... I
Ingress protection rating .................................................................................................................. IP 20
Overvoltage category............................................................................................................................. II
Line voltage range ..................................................................................... 100 V AC to 230 V AC ±10 %
...................................................................................................
Change of line voltage is not required!
Line frequency........................................................................................................................... 50/60 Hz
Current consumption .......................................................................................................... 4.0 to 8.0 A
Power consumption ........................................................................................................... max. 960 VA
Fuses ......................................................................................................................... 2x T 6.3 A/H/250 V
Summary of Contents for DirectFRAP
Page 1: ...DirectFRAP Operating Manual...
Page 62: ......