position.
14) MAX LOWER
%. This parameter stores the maximum voltage of lifting potentiometer output
connected to CNA#30. The min value acquisition is done closing the
DESCENT SW (DI1) and bringing the potentiometer in its min output
position.
15) PWM CHOP. START
%. This parameter stores the PWM value applied to MC coil and AUX COIL
for the first second of the output activation. It is expressed in percentage of
battery voltage.
16) PWM CHOP. WORK
%. This parameter stores the PWM value applied to MC coil and AUX COIL
after the first second of the output activation. It is expressed in percentage of
battery voltage.
17) PWM ON MAIN CONT
-
OFF: the inverter applies the battery voltage to the loads on the main
contactor coil connected to CNA#12.
-
ON: the PWM reduces the voltage on the main contactor
coil down to the
value programmed with “PWM CHOP. START” and “PWM CHOP.
WORK” parameters.
18) PWM ON AUX OUT
-
OFF: the inverter applies the battery voltage to the loads on the auxiliary
output coil connected to CAN#4.
-
ON: the PWM reduces the voltage on the main contactor
coil down to the
value programmed with “PWM CHOP. START” and “PWM CHOP.
WORK” parameters.