AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
-
EX.HYDRO: it drives the contactor for a hydraulic steering function when
the exclusive hydro input is active
-
FREE:
it is not used.
8) QUICK
INVERSION
It can be set:
-
NONE:
The quick inversion function is not managed (no effect when
CNA#7 switches over).
-
TIMED:
The quick inversion function is timed.
-
BELLY: The quick inversion function is managed but not timed.
9) SET MOTOR TEMPERATURE
It can be set:
-
ANALOG: An analogue sensor for the control of the motor temperature
is connected to CNA#22. Typically the temperature sensor is a PTC
(positive thermal coefficient resistance), providing the sensor
characteristic to Zapi the correct table can be loaded in the controller
software.
-
DIGITAL: A digital (on/off) sensor for the motor temperature monitoring
is connected to CNA#22 input.
-
NONE:
No temperature sensor is connected.
10) EV1 / 5
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV1 / 5 DRIVER
SHORTED” relative to the load connected to CNA#9 or CNA#8 is activated.
When set = ABSENT the diagnosis is not implemented.
11) EV2
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV2 DRIVER
SHORTED” relative to the load connected to CNA#11 is activated. When set
= ABSENT the diagnosis is not implemented.
12) EV3
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV3 DRIVER
SHORTED” relative to the load connected to CNA#33 is activated. When set
= ABSENT the diagnosis is not implemented.
13) EV4
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV4 DRIVER
SHORTED” relative to the load connected to CNA#34 is activated. When set
= ABSENT the diagnosis is not implemented.
14) DIAG. PEDAL WIRE KO
PRESENT/ABSENT: If set = PRESENT the diagnosis “PEDAL WIRE KO”,
relative to the connection of the two supply ends ( +12V, CNA#25; NPOT,
CNA#30) of the potentiometer in the accelerator , is activated. When set =
ABSENT the diagnosis is not implemented.
15) INVERSION MODE
ON/OFF: This parameter sets the logic of the Quick Inversion input. If set =
ON, the Quick Inversion switch is Normally Closed (function active when
switch opens). If set = OFF, the Quick Inversion switch is Normally Open
(function active when switch closes).