Page - 24/79
AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
A18
DI11
Input of the switch DI11. The input is activated when
the external switch is closed to -Batt. In the Sense Coil
version this input is connected to the AC motor sense
coil.
A19
DI5
Input of the switch DI5. The input is activated when it is
connected to +Batt. The default function is the
controller “
HORN
” input, closing the switch the horn
output is activated.
A20
DI1
Input of the switch DI1. The input is activated when it is
connected to +Batt. The default function is the
controller “
DESCENT
” enable input.
A21
DI12
Input of the switch DI12. The input is activated when
the external switch is closed to -Batt. It doesn’t have a
default function. In the Sense Coil version this input is
connected to the AC motor sense coil.
A22
THMOT
Traction motor thermal sensor input. The internal pull-
up is a fixed 2mA (Max 5V) source current.
A23
EVP2
Output of the second proportional electrovalve driver
(driving to –Batt).
A24
LOWER EVP1
Negative of the lower proportional electrovalve driver
(driving to –Batt).
A25
PENC
Encoder Positive Supply (+12/+5 Vdc)
A26
HORN OUT
Negative of the protected horn electrovalve driver
(driving to –Batt).
A27
CANL
Low level CAN-BUS voltage I/O.
A28 CANH
High level CAN-BUS voltage I/O.
A29
DI9
Input of the switch DI9. The input is activated when the
external switch is opened. The default function is the
controller “CUTBACK2” input, opening the switch truck
speed is reduced.
If "H&S FUNCTION" option is PRESENT, input is
activate when it is connected to +Batt and function is
the controller "
H&S
" (Hard and Soft) request input,
closing this input truck performances are modified.
Depending of wiring and internal jumper configuration,
it may be necessary an external connection, through a
diode, between H&S input and TILLER input.
A30
CPOTL/NPOT
Lift/Lower potentiometer wiper input. With the logic
hardware properly configured it can be used as
potentiometer negative reference. Using this input as
NPOT the diagnosis “PEDAL WIRE KO” is
implemented.
A31
DI4
Input of the switch DI4. The input is activated when it is
connected to +Batt. The default function is the
controller “
REV
” request input, closing this input truck
moves in backward direction.
A32
DI3
Input of the switch DI3. The input is activated when it is
connected to +Batt. The default function is the
controller “
FORWARD
” request input, closing this input
truck moves in forward direction.
A33
EV3
Output of the ON/OFF electrovalve EV3; 1,5 A