Page - 44/79
AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
parameter is not effective if the EVP1 is programmed like a On/Off valve.
30) MAX EVP
0 to 100. This parameter determines the maximum voltage applied on the
EVP1 when the position of the potentiometer is at the maximum. If the EVP1
is programmed like a On/Off valve this parameter determines the fixed
voltage applied on the electrovalve coil.
31) MIN EVP2
0 to 100. This parameter determines the minimum voltage applied on the
EVP2 when the position of the potentiometer is at the minimum. This
parameter is not effective if the EVP2 is programmed like a On/Off valve.
32) MAX EVP2
0 to 100. This parameter determines the maximum voltage applied on the
EVP2 when the position of the potentiometer is at the maximum. If the EVP2
is programmed like a On/Off valve this parameter determines the fixed
voltage applied on the electrovalve coil.
33) EVP OPEN DELAY
In seconds. It defines the opening ramp of the EVP1 electrovalve when
related output is set as Analog (refer to Set Option menu).
34) EVP CLOSE DELAY
In seconds. It defines the closing ramp of the EVP1 electrovalve when
related output is set as Analog (refer to Set Option menu).
35) EVP OPEN DELAY2
In seconds. It defines the opening ramp of the EVP2 electrovalve, when
related output is set as Analog (refer to Set Option menu).
36) EVP CLOSE DELAY2
In seconds. It defines the closing ramp of the EVP2 electrovalve, when
related output is set as Analog (refer to Set Option menu).
37) BACK SPEED
This is the percentage of the max speed that the traction can reach when the
inching function is active. The inching function can be used only if the option
TILLER SWITCH is set to SEAT.
38) BACKING TIME
This is the time duration of the inching function.