Notice
11.1
Shipping and storing
1>
Fusion splicer is an exact instrument; it must be transported with special
encasement.
2>
Do not put fusion splicer in too hot environment.
3>
Do not make it dew when storing.
11.2
Operating instructions
1>
Fusion splicer can only splice silex fiber.
2>
To avoid of too high voltage, do not open windshield and touch electrode.
3>
Do not touch electrode with hard thing when cleaning.
4>
Do not touch V-groove with hard thing when cleaning.
5>
Do not use KL-280 fusion splicer in flammable and explosive environment.
6>
Although normal working life of electrode is 3000 times, do not replace
electrode easily if arc is stable.
7>
Best to clean electrode about two or three times before splicing, and do the arc test.
Notice:
Because of the vulnerability, the electrode is not in the range of repair.
12 Addenda A Operating Fusion Splicer skillfully
This addendum can help you to resolve some questions by yourself.
1>
The screen is dark after starting machine.
Solutions:
1)
Check whether the electrical outlet is inserted.
2)
Check whether the voltage of P.S. is too low.
3) Check electric quantity of battery and charge battery in time.
2> “Exhausted Battery” is displayed on the bottom of screen after starting
Fusion Splicer and buzzer works continually.
Solutions:
1) If use battery, charge in time or replace the power supply.
3> The fiber can be reset as normal, but when setting gap, fiber is immovable
on the screen and “Setting gap” is displayed on the screen.
Solutions:
1) Raise the windshield, left and right clamps. The checking steps as follows:
2) Check whether broken fiber exists.
3) Check whether cleaved length is too short.
4) Check whether fiber matches with V-groove.
5) Check whether fiber is tail fiber.
4> The fiber can be reset as normal, but when setting gap, fiber moves
backwards continually, “Setting gap” and “Reload fiber” are displayed on screen.
Solutions:
Maybe there is too much dust on the lens of microscope, clean the aclinic
and upright lens with cotton swab until dust disappears, then try again.
5> The fiber can be reset as normal, but when setting gap, “Setting gap” is