GENERAL
Weights of specific chiller models vary significantly
as options are added. As a result, total weights,
weights at individual isolator positions, and actual
isolator selection at each position cannot be pub-
lished due to the thousands of possible combinations.
This information will be available when the specific
chiller/option selection is made from the local YORK
sales office. Be aware, weights will change with each
option along with possible isolator changes. Weights
and isolators may need to be recalculated when option
selections are changed.
Whenever the isolator option is ordered, the isolators
will be shipped loose with the chiller. Packed with the
isolators and also in the control panel information packet
is a drawing and table specifically for each chiller, based
on the option selection. The drawing and table will be
similar to the ones shown below in FIG. 8. The drawing
will show the isolator locations along with weight in
pounds and kilograms at the specific location, isolator
position, and location measurements for each isolator.
Location
X Distance inches (mm)
Y Distance inches (mm)
Vendor Number
Weight
R1
3.51 (89.2)
10.0 (254.0)
ND-D / Yellow
793.0 (359.7)
L1
3.51 (89.2)
78.0 (1981.2)
ND-D / Yellow
722.0 (327.49)
R2
48.5 (1231.9)
1.25 (31.8)
ND-D / Yellow
1236.0 (560.64)
L2
48.5 (1231.9)
86.75 (2203.5)
ND-D / Yellow
1222.0 (554.29)
R3
96.54 (2451.6)
1.25 (31.8)
ND-D / Yellow
1413.0 (640.93)
L3
96.54 (2451.6)
86.75 (2203.5)
ND-D / Yellow
1443.0 (654.53)
R4
142.41 (3617.2)
1.25 (31.8)
ND-DS / Yellow
1946.0 (882.69)
L4
142.41 (3617.2)
86.75 (2203.5)
ND-DS / Yellow
1889.0 (856.84)
R5
202.41 (5141.2)
1.25 (31.8)
ND-DS / Yellow
1831.0 (830.53)
L5
202.41 (5141.2)
86.75 (2203.5)
ND-DS / Yellow
1905.0 (864.09)
R6
252.53 (6414.3)
1.25 (31.8)
ND-D / Yellow
1318.0 (597.83)
L6
252.53 (6414.3)
86.75 (2203.5)
ND-D / Yellow
1350.0 (612.35)
R7
320.53 (8141.5)
1.25 (31.8)
ND-D / Yellow
1086.0 (492.6)
L7
320.53 (8141.5)
86.75 (2203.5)
ND-D / Yellow
1115.0 (505.76)
R8
353.62 (8982.0)
1.25 (31.8)
ND-D / Yellow
1018.0 (461.76)
L8
353.62 (8982.0)
86.75 (2203.5)
ND-D / Yellow
1063.0 (482.17)
FIG. 12 – SAMPLE PRINTOUT SUPPLIED IN THE ISOLATOR PACKAGE AND
IN THE CHILLER PANEL LITERATURE PACKET
LD11604
L1
L2
L3
L4
L5
L6
L7
L8
R1
R3
R5
R4
R2
R7
R8
R6
X
Y
Unit Shipping Wt.
(Display on unit data nameplate)
kg.
lbs.
8921
19668
Isolator Location Drawing
Order No: 051252591001
Line No: 1
Summary of Contents for YCAV0267E
Page 61: ...61 JOHNSON CONTROLS FORM 201 21 NM3 616 This intentionally left blank 6 ...
Page 73: ...73 JOHNSON CONTROLS FORM 201 21 NM3 616 This page intentionally left blank 6 ...
Page 89: ...89 JOHNSON CONTROLS FORM 201 21 NM3 616 6 035 20890 009 REV LOCATION LABEL CON T LD11141 ...
Page 146: ...146 JOHNSON CONTROLS FORM 201 21 NM3 616 TECHNICAL DATA This page intentionally left blank ...
Page 147: ...147 JOHNSON CONTROLS FORM 201 21 NM3 616 6 This page intentionally left blank ...
Page 247: ...247 JOHNSON CONTROLS FORM 201 21 NM3 616 This page intentionally left blank ...
Page 269: ...269 JOHNSON CONTROLS FORM 201 21 NM3 616 This page intentionally left blank 8 ...
Page 289: ...289 JOHNSON CONTROLS FORM 201 21 NM3 616 8 This page intentionally left blank ...
Page 317: ...317 JOHNSON CONTROLS FORM 201 21 NM3 616 8 This page intentionally left blank ...
Page 348: ...348 JOHNSON CONTROLS FORM 201 21 NM3 616 MAINTENANCE NOTES ...
Page 349: ...349 JOHNSON CONTROLS FORM 201 21 NM3 616 9 NOTES ...