Table 23: YV28 to YV50 VFD two-stage medium static modulating power exhaust
Comp. 1
Comp. 2
Min
disconnect
rating
Min
disconnect
rating/120V
trans
Size
(tons)
Nominal
unit
voltage
RLA LRA RLA LRA
OD fan
motors
each
FLA
OD fan
motors
each
FLA
Supply
blower
motor
FLA
Supply
blower
motor
LRA
Power
exh
VFD
FLA
Power
exh
motor
LRA
120 V
trans
FLA
MCA
A
Max
f/b
size
A
FLA
LRA
MCA
with
120 V
trans
A
Max
f/b
size
with
120V
trans
A
FLA
LRA
208-3-60 41.0 304 41.0 304
4.0
21.0
28.0
173.44
9.6
21.0
14.4
146
175
156
907
160
200
173
922
230-3-60 41.0 304 41.0 304
4.2
21.0
28.0
173.44
9.6
21.0
13.0
147
175
157
907
160
200
172
920
460-3-60 19.2 147 19.2 147
2.1
10.5
14.0
86.72
4.8
10.5
6.5
70
80
75
444
77
90
83
450
YV28
(27.5)
575-3-60 16.7 122 16.7 122
1.6
7.8
11.0
71.77
4.9
7.8
5.2
60
75
64
363
65
80
70
368
208-3-60 44.2 315 44.2 315
4.0
21.0
28.0
173.44
9.6
21.0
14.4
153
175
163
929
167
200
180
944
230-3-60 44.2 315 44.2 315
4.2
21.0
28.0
173.44
9.6
21.0
13.0
154
175
164
929
167
200
179
942
460-3-60 22.4 158 22.4 158
2.1
10.5
14.0
86.72
4.8
10.5
6.5
78
100
83
466
84
100
90
472
YV30
(30)
575-3-60 18.6 136 18.6 136
1.6
7.8
11.0
71.77
4.9
7.8
5.2
64
80
68
391
69
80
74
396
208-3-60 48.1 351 48.1 351
4.0
21.0
28.0
173.44
9.6
21.0
14.4
162
200
172 1001 176
200
189 1016
230-3-60 48.1 351 48.1 351
4.2
21.0
28.0
173.44
9.6
21.0
13.0
163
200
173 1001 176
200
188 1014
460-3-60 24.7 197 24.7 197
2.1
10.5
14.0
86.72
4.8
10.5
6.5
83
100
88
544
89
110
96
550
YV35
(35)
575-3-60 22.4 135 22.4 135
1.6
7.8
11.0
71.77
4.9
7.8
5.2
73
90
77
389
78
100
83
394
208-3-60 48.1 351 48.1 351
4.0
21.0
42.0
234
15.2
39.6
14.4
181
225
195 1099 196
225
211 1114
230-3-60 48.1 351 48.1 351
4.2
21.0
42.0
234
15.2
39.6
13.0
182
225
196 1099 195
225
211 1112
460-3-60 24.7 197 24.7 197
2.1
10.5
21.0
117
8.2
19.8
6.5
93
110
100
593
100
110
108
599
YV40
(40)
575-3-60 22.4 135 22.4 135
1.6
7.8
18.0
95.94
6.1
15.8
5.2
81
100
87
429
86
100
93
434
208-3-60 67.3 485 67.3 485
7.2
39.6
42.0
234
15.2
39.6
14.4
237
300
254 1442 252
300
270 1456
230-3-60 67.3 485 67.3 485
6.8
39.6
42.0
234
15.2
39.6
13.0
236
300
252 1442 249
300
267 1455
460-3-60 32.7 215 32.7 215
3.4
19.8
21.0
117
8.2
19.8
6.5
116
125
124
666
123
150
132
672
YV50
(50)
575-3-60 26.3 175 26.3 175
2.7
15.8
18.0
95.94
6.1
15.8
5.2
94
110
101
541
99
125
107
546
Installation Manual: YORK
®
Sun™ Select YV28 to YV50
47
Johnson Controls Ducted Systems
Summary of Contents for Sun Select YV28
Page 2: ...Tested in accordance with ...
Page 105: ...Installation Manual YORK Sun Select YV28 to YV50 105 Johnson Controls Ducted Systems ...
Page 106: ...Installation Manual YORK Sun Select YV28 to YV50 106 Johnson Controls Ducted Systems ...
Page 107: ...Installation Manual YORK Sun Select YV28 to YV50 107 Johnson Controls Ducted Systems ...
Page 108: ...Installation Manual YORK Sun Select YV28 to YV50 108 Johnson Controls Ducted Systems ...
Page 109: ...Installation Manual YORK Sun Select YV28 to YV50 109 Johnson Controls Ducted Systems ...